• WhatsApp:+86-19892834301
  • Email: automantool@hotmail.com
  • Skype:autoobdtop
Home > Products  > Auto Repair Software

2024.11 Caterpillar Cat ET 2024C Electronic Technician Diagnostic Software 2024 Latest Version

Item No. RS571 In Stock. History sold.

    0 out of 5

    0 global ratings

    5 stars:0%
    4 stars:0%
    3 stars:0%
    2 stars:0%
    1 stars:0%

ratings| answered questions
Latest price:$179.00
Buy Now: $ 159.00 11% off

Fast Shipping & No Tax

US Check: Ship from US

UK Check: Ship from UK

EU Check: Ship from Czech

Looking for help? Please contact Whatsapp: +86-19892834301

Shipping:
Free Shipping
Express Shipping ServiceEstimated delivery time: 3-5 Working Days
Quantity:
- +
Stock:32
Add to Wish List
continue
Weight:
0.1 KG
Package:

Related Download Files

Share

2024.11 Caterpillar Cat ET 2024C Electronic Technician Diagnostic Software 2024 Latest Version


Caterpillar Electronic Technician (ET) Software Table of Contents (Check ET Technician Brochure for quick review)

  • About Caterpillar Electronic Technician 2024C

  • Important Notice and Installation Instructions

  • PC, Communication Hardware, and Cable Requirements

  • Software Download Links

  • Supported CAT Machines and Engines

  • Error When Launching Service Tool

  • How to update CAT ET?

  • Updates by version


The Electronic Technician is Caterpillar computer diagnostic software. It communicates diagnoses and services electronically controlled Caterpillar engines and machines. When connected to an ECM, a technician can diagnose existing and potential problems, configure the product, and obtain data for analysis.


If you work on Caterpillar machines, you will definitely use this diagnostic software. The Electronic Technician has all the tools and capabilities you'll need to diagnose and successfully repair your CAT off-road and on-road machines.


The ET 2024 v1.1 software replaces all the previous versions of CAT ET with stability, new driver support futures, and a smoother performance with Windows 11. The Caterpillar program can help technicians diagnose existing and potential problems with their electronically controlled Caterpillar Engines and Machines.



Please check the following product 18-Bit CAT Factory Passwords to unlock/change advanced ECM parameters.


The Screenshot for the CAT ET Connection Initialization


1.png



Important Notice and Installation Instructions


IMPORTANT NOTICE!

Installation and activation of CAT ET 2024C software are possible only with remote assistance using Teamviewer.

We provide ONLY offline activation methods.


Simple Steps to Purchase and Set Up CAT ET 2024C

  • Start Your Order: Click the BUY NOW button to proceed to checkout.

  • Receive Your Download Link: After payment, check your email. You will receive a download link within a few minutes.


PC, Communication Hardware, and Cable Requirements

Potential compatibility issues!

  • Laptops with ARM CPUs (e.g., Snapdragon 8cx, Microsoft SQ1) are not supported.

  • As of the 2020B release, the CAT ET service tool no longer supports Windows 7. Installation is possible but not guaranteed to be stable.


Supported Hardware

The following communication adapters are supported:

  • Caterpillar Comm Adapter 2

  • Caterpillar Comm Adapter 3

  • Nexiq USB-Link 1/2/3(for On-Highway only)

  • RP-1210C Compliant Communication Adapters, such as:

    • Noregon® DLA+ 2.0 Adapter Kit

    • Other compliant adapters: Please check with us if your adapter is not on this list.


PC Requirements for CAT ET 2024

Recommended configurations:

  • PC with a 2.0 GHz dual-core processor

  • 4 GB RAM

  • 5 GB of available hard disk space

  • 12-inch or larger screen, Windows desktop compatible

  • Microsoft Windows™ 8.1 Professional, Windows 10 Professional, or Windows 11 Pro (Note: Windows 8 RT is not supported)

  • RS232 port with 16550AF UART or compatible (for use with Comm Adapter II)

  • USB v1.1, v2.0, v3.0, or v3.1 port (for use with Comm Adapter 3)

  • Ethernet RJ45 connector (or Wi-Fi adapter)

  • Built-in pointing device or mouse

  • Microsoft Internet Explorer version 11, Microsoft Edge, Firefox, or Chrome browsers are recommended.

  • Note: The most recent version of Microsoft Internet Explorer may not be validated to work with the service tool.

  • Wi-Fi (for the Wireless Comm Adapter 3)


Software Download Links

  • CAT Electronic Technician 2024B v1.0 (578 MB):

    • Download Link

  • Comms Adapter 3 V4.7.0.77 driver (71 MB):

    • Download Link


Supported CAT Machines and Engines

Engines

  • Electric Power

  • Electric Power Generation

  • Industrial

  • Marine Power Systems

  • Oil and Gas

Machines

  • Articulated Trucks

  • Asphalt Pavers

  • Backhoe Loaders

  • Cold Planers

  • Compactors

  • Dozers

  • Drills

  • Excavators

  • Feller Bunchers

  • Forest Machines

  • Forwarders

  • Harvesters

  • Hydraulic Mining Shovels

  • Knuckleboom Loaders

  • Material Handlers

  • Motor Graders

  • Off-Highway Trucks

  • Pipelayers

  • Road Reclaimers

  • Site Prep Tractors

  • Skid Steer and Compact Track Loaders

  • Skidders

  • Telehandlers

  • Track Loaders

  • Underground - Hard Rock

  • Underground - Longwall

  • Underground - Room and Pillar

  • Utility Vehicles

  • Wheel Dozers

  • Wheel Excavators

  • Wheel Loaders

  • Wheel Tractor-Scrapers


Error When Launching Service Tool (The complete list of known Electronic Technician error codes and resolutions)

There is a Microsoft issue with upgrading libraries during an installation involving certain versions of the C++ redistributable. After a successful service tool installation, when trying to run the service tool for the first time, one of the following errors may occasionally appear: “The entry point could not be located in api-ms-win-crt-runtime” or “The program can't start because mfc140u.dll is missing from your computer.” If either of these messages is displayed, follow the procedure below. This procedure requires administrator rights.

  1. Open the Start Menu

  2. Click the Control Panel

  3. Click the "Programs and Features" icon. If there is only a "Programs" icon, click the "Uninstall a Program" link next to the icon.

  4. Find the program entry for either "Microsoft Visual C++ 2015 Redistributable (x86) - 14.0.24215" or "Microsoft Visual C++ 2015 Redistributable (x86) - 14.0.242151"

  5. If the specified program entry is not found, proceed directly to step 8

  6. If the specified program entry is found:

    1. Right-click the specified program entry

    2. Click the Change menu item

    3. Click the Repair button in the dialog that appears

    4. Verify that the service tool runs properly

  7. If the service tool still displays an error after the Repair operation:

    1. Right-click the specified program entry

    2. Click the Uninstall menu item

  8. Click the link below to download an x86 version of the runtime package from Microsoft. https://download.microsoft.com/download/6/A/A/6AA4EDFF-645B-48C5-81CC-ED5963AEAD48/vc_redist.x86.exe

  9. Install the downloaded package

  10. Verify that the service tool runs properly

  11. If the service tool still displays an error, please send an email to the support department.


Frequently Asked Questions (FAQ)

How to update CAT ET?

CAT ET does not support in-application updates. Before the update, check what's new in the Updates by Version section. If you need an update, please follow these steps:

  1. Place an order for the latest revision of CAT ET

  2. Download the latest version of CAT ET from the order download page.

  3. Uninstall the existing version of CAT ET from your computer.

  4. Install the new version following the on-screen instructions.

  5. After installation, contact us to activate your license and use the updated version.


What's New - Updates by Version

2024C

Automatic Connection Preferences

Users are now able to change multiple automatic connection preferences for the service tool and WinFlash. After navigating to the Preferences dialog, users may enable the service tool to connect automatically when opened in service and/or flash mode. Both options may also be disabled if the user wishes to connect manually.


2024B

No significant new features or feature enhancements


2024A

Feature Protection System (FPS) Default Browser Update

During flash, a progress bar that tracks the flash progress will display over the service tool application icon on the taskbar. This allows the user to work in other windows or applications without having to switch back and forth to monitor the progress of the flash.


Trainer Update – 995 Large Wheel Loader


The 995 Large Wheel Loader has been added to the Trainer application.


2023C

Flash Progress Bar

The default browser selection options for the Feature Protection System (FPS) have been updated. After installation or upgrade, “Default Browser” will be the default browser selected, eliminating the need for technicians to manually change the setting. Internet Explorer remains a selectable option.


2023A

Graphing Colors

The color schemes for features that use graphing, such as Real Time Graph, Data Logger, or Histograms, have been changed. The manual color selection process for the Real Time Graph and the Data Logger features has also been updated. User-selected graph colors are now maintained through any disconnections and only change when the user chooses to revert to the default color settings or selects different graph colors manually.


2022C and Earlier

No significant new features or feature enhancements for these versions.


What's New - 2022C

No significant new features or feature enhancements


What's New - 2022B

New Hot Key to Reposition Service Tool Window

When the service tool window is not showing in the viewable area, there is now a hotkey to allow the user to recover the window. CTRL-ALT-H will reposition the window in the viewable area. The original window proportions will be preserved, unless they exceed the main monitor size. The window will be resized to fit the main monitor dimensions in such cases.


What's New - 2022A

Microsoft® Windows™ 11 Compatibility

Service tool testing has been performed, and the service tool is compatible with Windows 11.

ECM File Replacement Compare Feature

The service tool now has an ECM Replacement File Compare feature for troubleshooting purposes. This feature allows the user to compare one ECM replacement file with another from within the ECM Replacement feature screen. The feature will highlight the differences between the selected files as a whole, or the user may select the “only show differences” checkbox.

Configuration Group Headings on ECM Replacement Feature

To help the user find ECM replacement configuration items more quickly, configuration items in the ECM Replacement, Fleet Configuration, and Product ECM features are now grouped under their group sub-headings, as is done in the main configuration feature.


What's New - 2021C

Feature Protection System Password Copy

The Feature Protection System (FPS) has a new "Easy Copy" link to copy passwords in a single operation. The service tool can automatically obtain the passwords from the clipboard and populate the FPS dialog. The service tool dialog also has a new "Easy Paste" button that allows the user to paste data in the correct format from the clipboard. Passwords can still be pasted using customary copy/paste operations, such as the context menu or the CTRL + V hotkey combination.

Screen Resolution Requirement Update

The minimum requirement for screen resolution has been updated to 1366x768, or at least 1366 pixels horizontally and at least 768 pixels vertically. The recommended screen resolution is at least 1600x1200. The service tool window displays with a minimum size of 1024x680.


What's New - 2021B

End of Support for Windows 8

Microsoft is ending extended support for Windows 8 as of January 2023. The service tool will be ending support for Windows 8 after the 2021C release.


Calibration Images


Images attached to calibration instructions will no longer need to be opened manually to be viewed by a technician. The service tool will now have split user interface windows for calibrations that display pictures. This will allow the technician to see the images without having to navigate away from the instructions.

Images may be opened into individual windows and resized for better clarity. The user interface for calibrations that do not display pictures will remain unchanged.

Default PC Browser

The service tool will no longer automatically launch web pages in Microsoft Internet Explorer. Web pages will now launch in whatever application is configured as the default internet browser. Certain web pages require a specific browser and may launch in a different browser.


What's New - 2021A

No significant new features or feature enhancements


What's New - 2020C

No significant new features or feature enhancements


What's New - 2020B

Trainer Update – 299D3

The 299D3 Skid Steer Loader has been added to the Trainer application.


What's New - 2020A

Product Status Report Updates

The Product Status Report has been updated to include throttle configuration information.

Built-in Factory Password Generator

The experimental feature allows you to decode (18-Bit passwords not supported) factory passwords


What's New - 2019C

Indication of Selected Communications Adapter

The service tool now displays the selected communications adapter when the service tool is disconnected. The adapter name is displayed in the status area at the bottom right of the service tool window.

End of Support for Windows 7

Microsoft is ending extended support for Windows 7 as of January 2020. The service tool will be ending support for Windows 7 as of the 2020A release.


What's New - CAT ET 2019B

Automatic Product Status Report (PSR) Upload

The service tool includes a new tool that automatically uploads Product Status Reports. The tool scans for newly generated Product Status Reports and uploads them when an internet connection is available. The default is that automatic report uploading is enabled. The Preferences dialog has the option to disable the tool.


What's New - 2019A

ECM Naming Changes

Certain ECMs connect to the service tool over two data links at the same time. The service tool shows a message popup when the ECM is only detected on one link. The service tool has been changed to add the text **INCOMPLETE** in the ECM name when the connection is incomplete. Service tool features that display a connection icon also use a new icon for an incomplete connection.


What's New - 2018C

No significant new features or feature enhancements


What's New - 2018B

CEOS Fleet Configuration File TOP

A CEOS (Customer Electronic Option Selection) Fleet Configuration File can be created/modified for an engine using the Service Tool. This is available in connected and disconnected mode.

Error When Launching Service Tool

There is a Microsoft issue with upgrading libraries during an installation involving certain versions of the C++ redistributable. After a successful service tool installation, when trying to run the service tool for the first time, one of the following errors may occasionally appear: “The entry point could not be located in api-ms-win-crt-runtime” or “The program can't start because mfc140u.dll is missing from your computer.”

If either of these messages is displayed, please let us know and we will send you by step troubleshooting guide. This procedure requires administrator rights.

Service Tool License Corruption Issues with Windows 10 Updates

Windows 10 updates 1709 and 1803 will corrupt service tool licenses. Future Windows 10 updates may do the same

If either of the license error messages is displayed, please let us know and we will send you by step troubleshooting guide.


What's New - 2018A

Trainer Update - 988K XE Wheel Loader

The 988K XE Wheel Loader has been added to the Trainer application.


What's New - 2017C

Preferences Option to Save a Product Status Report to PDF

The Preferences dialog for the Product Status Report has changed. The dialog contains a new checkbox to automatically save a Product Status Report as a PDF file when the report is created. The service tool will continue to automatically save Product Status Reports as an XML file.



What's New - 2017B

Product Status Report Updates
The Product Status Report has been updated to include certain history features supported by the ECM, such as the after-treatment Regeneration History and the Service Test History.
Winflash Screen Update
The screen for the Winflash feature has been updated. A new Expand All button opens all sections of the screen to show all details for ECMs detected by WinFlash. A new Collapse All button hides all sections of the screen, except for header rows showing detected ECM names.



Customer Questions & Answers
Customer Reviews

0 Stars of 5,0 Reviews.

5 stars:0%
4 stars:0%
3 stars:0%
2 stars:0%
1 stars:0%

Share your thoughts with other customers.

Write a review
Top customer reviews

Address:Guangming District ShenZhen,China (P.C.:518112)    E-Mail: automantool@hotmail.com

Copyright © 2015 Shenzhen Automan Technology Co., Ltd. A Professional OBD Manufacturer. All rights reserved.

Payment: